#1.2 Flow measurement techniques

There are many ways to characterize real flows, all of which can fall into two distinct categories. On the one hand, optical diagnosis can provide spatially-resolved measurement of the velocity, density or pressure fields, at the expense of requiring heavy experimental setups, making it suited for capturing complex and large-scale flow phenomena. For instance, Schlieren imaging is the oldest form of optical characterization, and relies on light deflection by refractive index fluctuations, creating a black-and-white image showing the flow density distribution. LDV is widely used to make direct point velocity measurements by focusing two coherent laser beams on the measurement zone. The resulting fluctuating intensity generated by scattering on a particle crossing the measurement volume is directly proportional to the flow velocity. More modern techniques, like PIV and PLIF, rely on seeding the medium with a substance which fluoresces or reflects light. Quick laser pulses synchronized with camera captures are used to map the seeding particles in space, and numerical correlation techniques are used to infer the velocity, concentration, temperature or pressure fields.

Δp static pressure totalpressure flow
Figure 1.2.
Measurement principle of a Pitot tube in the Prandtl antenna configuration.

Sensors, on the other hand, mean that point measurements are performed by a probe interacting with the flow. The historical example is the Pitot tube (Pitot 1732)19, still widely used for measuring airspeed in commercial and military aircraft. A protruding probe generates two pressure zones, total and static, their difference being proportional to the flow speed at the probe tip. The downside of such a method is the size of the apparatus, which averages out both spatial and temporal velocity variations. Another example is the hot wire, which will be discussed in detail in section 1.2.1, relying on forced convection around a heated element to perform finer and more localized velocity field measurements. However, there is room for improvement in sensor designs to meet the spatiotemporal resolution requirements discussed above, meaning miniaturizing them down to the micrometer range and increasing the bandwidth to 100 kHz. This is why, in the last fifty years, considerable miniaturization efforts have been made to reduce the size and time constants of the sensing elements, taking advantage of the developments in MEMS manufacturing techniques.

#1.2.1 Hot wires

#Working principle

A hot-wire anemometer uses a fine wire which is electrically heated to some overheat point (figure 1.3). Its average temperature settles down to an equilibrium depending on three power contributions:Radiative effects are negligible, as they make for a 10–4 fraction of the power budget at ambient pressure conditions (Comte-Bellot 1976)20.


  1. Joule heating power,
  2. end conduction thermal losses (undesirable because not velocity-dependent),
  3. thermal losses to the fluid: conduction (not velocity-dependent) and forced convection (dependent on the flow velocity).
supportprongs Thermal boundary layer to control circuit flow direction Joule-heated wire ΔR/R = TCR· ΔT Heat transfer to the fluid
Figure 1.3.
Measurement principle of a hot wire anemometer.

End conduction losses depend solely on the conductor’s thermal conductivity, and are unwanted because they undermine the device’s sensitivity. The thermal losses to the fluid split into two terms, conduction and forced convection. The ratio between total heat transfer and conductive heat transfer is expressed by the Nusselt number \text{Nu} = \frac{hd}{k}, where k is the thermal conductivity of the fluid, h the convection coefficient and d the characteristic dimension, here the diameter of the wire. Nu gives an image of the efficiency of forced convection, which is desired to be high. King (1914)21 empirically expressed the Nusselt number dependence on the Reynolds number with calibration constants A and B \text{Nu} = A + B\sqrt{\text{Re}}, which means that the convective part of heat transfer to the flow varies with the square root of the velocity. Considering an infinitely long cylinder (neglecting the end conduction effects), the power equilibrium over a segment length \ell of resistance R_\text w heated by a current I can be expressed: R_\text w I^2 = \pi d h \ell \Delta T = \text{Nu} \cdot \pi \ell k \Delta T.

For all metals, electrical resistivity depends on the temperature with the relationship R_\text w - R_0 = R_0 \cdot \text{TCR} (T - T_0), defining the TCR expressed in \left[\text{K}^{-1}\right] as a constant property of the material, and key contributor to the device’s sensitivity. Usually, hot wires are chosen with high TCR metals, like tungsten, nickel or platinum. As a consequence, at constant current, there is a dependence of the voltage readout E_\text w at the wire terminals on the flow velocity U: \frac{E_\text w^2}{R_\text w} = \left(A + B \sqrt{U}\right)(T - T_0).

The exact occurrence of the first hot wire remains uncertain, but they have been extensively used in research since the 1910s, in order to obtain finer velocity measurements than what Pitot tubes could perform. After the Second World War, the electronics department of the Danish company DISA launched Dantec Dynamics, which quickly became the industry leader in thermal anemometry. Their 55A series probes and controllers were extensively used in both academic research and engineering, accompanying aerospace innovations during the Cold War. After more than fifty years of innovation, they dominate the market and offer a wide range of probes and controllers, and have also diversified to other flow measurement techniques.

The variety of hot wire probes manufactured by Dantec Dynamics, the industry leader in thermal anemometry. Image taken from Dantec Dynamics’ website.
Figure 1.4.
The variety of hot wire probes manufactured by Dantec Dynamics, the industry leader in thermal anemometry. Image taken from Dantec Dynamics’ website.

#Constant temperature anemometry

Early hot wires were operated in CC mode, the most common configuration being the hot wire incorporated into a Wheatstone bridge. The bridge voltage sets the overheat value while the arm imbalance reacts proportionally to the probe resistance. While CC anemometers worked well to measure mean flow velocities, the need to also catch fast fluctuations quickly emerged. However, engineers faced a prominent “lag” effect (Dryden & Kuethe 1930)22, due to the thermal time constant of the wire itself, which prevented any high-frequency content from being captured.

The idea to broaden the bandwidth by operating hot wires at a constant resistance (i.e. temperature) was first introduced by Ziegler (1934)23, and laid the groundwork for substantial improvements in frequency response. The first commercial CTA system was launched in 1958 by DISA. In the late 60s, the emergence of low-cost high-performance IC amplifiers enabled quick developments in control theory to improve the frequency response to 16 kHz (Freymuth 1967)24, then 25 kHz (Freymuth 1977)25. Ultimately, careful component selection and precise fine-tuning of the control loop time constants enabled Watmuff (1994)26 to develop a research-grade 250-kHz anemometer which is still in use at Princeton and Melbourne universities. Currently, Dantec advertises a 450-kHz bandwidth for their latest Streamline Pro system. To illustrate the benefits of closed-loop control, Ghouila-Houri et al. (2017)27 showed the open-loop time constant of the HTGS (which is presented in detail in section ¿sec:thermal_wsss?) heating element to be around one millisecond, limiting the bandwidth to about one kilohertz. By using a CTA controller, the HTGS response time has been improved more than ten-fold, enabling energy spectra to be obtained up to 13 kHz (Ghouila-Houri et al. 2021)28.

The core block diagram of a CTA has been established by Perry & Morrison (1971)29 (figure 1.5). The hot wire is placed into a Wheatstone bridge regulated with a feedback loop. At equilibrium, the bridge’s arm resistances are equal, i.e. the hot wire Z_\text{HW} matches the potentiometer Z_\text{OH}, assuming a bridge ratio of 1. The error voltage E_\text{i} equals zero, and a DC voltage E_\text{o} is fed at the top of the bridge. Resistance fluctuations in the hot wire will unbalance the bridge and create a small error voltage E_\text{i}. The differential amplifier compensates to equalize both of its inputs, bringing the bridge back to equilibrium. The fluctuating bridge voltage serves as the controller’s output, giving an image of the power compensation needed to maintain constant temperature. The hot wire overheat (OH, temperature increase from ambient) can be tuned with the Z_\text{OH} potentiometer. Assuming square-root resistance dependence on flow velocity, the power compensation image E_\text O^2 of the controller also scales with the square root of the flow velocity:

E_\text O^2 = A + B\sqrt U.

ZHW Eo Eo = Eo + eo iHW ZA ZC K I ZOH Eqi diff.amplifier currentbooster CTAoutput Ei = Ei + ei Io = Io + io
Figure 1.5.
Perry-type control loop block diagram. Adapted from Perry & Morrison (1971)29.

#Micro- and nanoscale hot wires

While temporal resolution was greatly improved by refining control electronics, spatial resolution still matters in order to fully capture fine details of the turbulence. Commercially available hot-wire probes are made with 1 mm long wires with typical diameters of 5 µm. In this context, advances in microfabrication for solid-state electronics led to the emergence of the MEMS field, opening the way to miniaturized flow sensors. Jiang & Ho (1994)30 at UCLA/CalTech first reported the successful fabrication of a 160 × 1 × 0.5 µm hot wire out of polysilicon, in order to address both spatial resolution and individual by-hand manufacturing issues. During the nineties, their team extensively refined and characterized iterations of this design to improve the sensitivity and thermal bandwidth (Mischler et al. 1995)31.

Since 2006, a team at Princeton University has been developing an out-of-plane nanoscale hot wire (Bailey et al. 2010)10, (Kunkel et al. 2006)32, which they called the NSTAP sensor series. The aim was to shrink the sensor wire down to 100 × 60 × 2 nm, in order to capture the very smallest turbulent eddies at high-Reynolds, and overcame the spatial filtering effect. More recently, they introduced an ultrafast temperature probe (cold wire) (Arwatz et al. 2015)33, and an X-shaped probe to measure two components of the velocity vector (Fu et al. 2019)34. The thesis work of Samie (2018)35 reported extensive modeling and in-flow characterizations of NSTAP probes, using Jonathan Watmuff’s optimized CTA controllers in high-Reynolds flows, and showed exceptional agreement with analytical and numerical models.

Simultaneously, our research team at IEMN developed a similar design, with nanocrystalline diamond prongs for mechanical robustness and minimal end conduction (Talbi et al. 2015)36. The 200 × 5 × 2 µm sensing wire was made of a stress-compensated Ni/W multi-layer and the device characterized in steady flows up to 30 m/s. More recently, a Montpellier University team reported the fabrication of the µTA, a similar microscale thermal anemometer, with a 60 × 1.5 × 0.2 µm platinum heater supported by silicon prongs (Baradel et al. 2021)37. It was statically characterized in a turbulent boundary layer with a 25 m/s freestream velocity.

Figure 1.6.
Micro- and nanoscale hot wires reported in recent research.

(a) 100 × 60 × 2 nm  developed by Arwatz et al. (2015)33 at Princeton University.
(b) Linear array of 200 × 5 × 2 µm hot wires made by Talbi et al. (2015)36 at
(c) 60 × 1.5 × 0.2 µm µTA probe (right) by Baradel et al. (2021)37 at Montpellier University.

#1.2.2 Wall shear stress sensors

#The boundary layer

Close to a solid surface in contact with a fluid, a no-slip condition is forced on the fluid due to its viscosity. This results in a velocity gradient ranging from u = 0 at y = 0 on the wall surface, to u = u_\infty infinitely far away (figure 1.7). The profile of this gradient strongly depends on the Reynolds number, wall roughness, geometry and pressure distribution. The boundary layer is defined as the zone between the wall and the point where flow velocity reaches 99 % of the freestream velocity. Consequently, a WSS \tau_\text w develops at the wall-fluid interface, depending solely on the fluid’s dynamic viscosity \mu = \rho\nu and the velocity gradient on the wall: \tau_\text w = \mu \left. \frac{\partial u}{\partial y} \right|_{y=0}

τw x y solid wall boundarylayer freestreamflow u(y) z u(y) = 0.99u∞ u∞
Figure 1.7.
Schematic representation of the viscous boundary layer and associated wall shear stress.

This WSS (or skin friction) is one of the main contributors to the aerodynamic drag force, the other being the pressure drop created by flow separation on the back-facing surfaces. While measuring the WSS value is of great interest for optimizing surfaces and geometries for drag reduction, it also gives information about freestream velocity and boundary layer vorticity content. Figure 1.8 shows a classification of the existing WSS measurement techniques. It is possible to infer the WSS value with boundary layer profiling, i.e. measuring the u(y) velocity profile by multiple hot-wire measurements. However, this is valid only for stationary, well-developed flows because of the time needed to perform the series of measurements. Moreover, this indirect inference of the wall shear stress needs backup from a direct measurement such as the oil film technique. An oil droplet is deposited on the wall, which will be spread out by the wall shear force. Knowing the viscosity and optical index of the oil, an interferometric measurement of its thickness gives a direct measure of the WSS. The focus of this work is mainly on sensors, therefore sensor-based methods are developed in the following paragraphs. In particular, emphasis is placed on those compatible with microfabrication processes: obstacles, balances and thermal sensors. Additionally, there is much more literature on balances and thermal sensors than on obstacle-based methods, because they offer higher sensitivity and spatial resolution, and are non-intrusive since they do not require any protruding structures.

Wall shear stress measurement Wall similarity Analogies Heat transfer Mass transfer Preston tube Stanton tube Obstacles Velocity profiling Liquid tracers (oil film) Momentum balance Direct measurement Razor blade Fences/pillars/cantilevers Static pressure holes
Figure 1.8.
Classification of WSS measurement techniques proposed by Winter (1979)38. MEMS sensors can be sorted in the categories shown in bold.
wall pressureintakes Prestontube Stantontube Razorblade u(y) Fence Pillar
Figure 1.9.
Various obstacle designs. Adapted from IC2 (2019)39.

#Obstacles

In a similar manner to Pitot tubes, obstacles can be used to measure WSS by obstructing the flow at wall proximity. Because of the large space-averaging due to their size, they are limited to flows with thick boundary layers. Concerning fences and pillars nonetheless, there have been miniaturization efforts, with piezoresistive or optical transduction methods replacing the pressure intakes. Ernst Obermeier’s team at TU Berlin, while reporting significant developments in thermal flow sensors (discussed below), also developed a 5 000 × 315 × 10 µm MEMS fence sensor, with piezoresistors placed at the stress concentration zones (von Papen et al. 2004)40. Over the late 2000s and early 2010s, they refined the design and conducted static and dynamic characterizations in a vortex rig flow (Savelsberg et al. 2012)41. However, the authors noted that the natural resonance frequency of the structure, around 2 kHz, was a limiting factor to dynamically characterize the turbulent boundary layer.

Pillars, while presenting the same mechanical filtering effect as fences, can be placed in arrays in order to 2D map the two components of the wall shear force. The concept was first implemented by Große et al. (2006)42 at Aachen University, with 200 to 300-µm-high polymer pillars with a reflective tip for optical characterizations. They have been characterized in a deionized water flow, in order to obtain high shear rates at low Reynolds (\leq 1). They successfully demonstrated 2D mapping of WSS with a spatial resolution of 125 µm in both water and air (Gnanamanickam et al. 2013)43.

However, the limitations inherent to obstacle-based methods, even at MEMS scales, hindered further development, and little to no follow-up research appears to have been reported in the 2010s and 2020s. In contrast, other approaches to WSS measurement have continued to evolve and have demonstrated significant progress, namely direct and thermal methods.

wall u(y) floatingmass displacementẟ m k
Figure 1.10.
Direct shear measurement principle. Adapted from Sheplak et al. (2006)44. The WSS \tau_\text w is the measured force F = k\delta divided by the wet area A.

#Direct methods

Mechanical systems can perform a direct measurement of the WSS value without needing a protruding obstacle. A floating mass-spring system flush-mounted to a wall will undergo a displacement \delta, which can be measured by several transduction methods (figure 1.10). Consequently, the sensitivity depends solely on the spring’s stiffness k and wet area A of the mass. This results in accurate and calibration-free WSS measurement: \tau_\text w = k\delta/A. As a downside, these designs are more complex to microfabricate than fences or pillars. In order to convert the displacement to a readout value, several transduction principles can be employed: combed capacitances, strain gauges, piezoelectric crystals and optical interferometry. Froude (1872)45 pioneered direct WSS measurement in water flow, by flush-mounting a floating plate to a ship hull. During the 50s and 60s, the developments of electric transduction methods enabled sensitivity and temporal resolution improvements, and WSS balances were extensively used in wind tunnels and on experimental aircraft and rockets.

The first microfabricated WSS balance was developed during the PhD thesis of Schmidt (1988)46 at MIT, out of polyimide deposited on an oxidized silicon wafer. This laid the groundwork for the most common direct shear sensor architecture, consisting of a floating element supported by a parallel linkage spring array, and using capacitive transducers to convert displacement into a readout voltage. A similar design was introduced with piezoresistive transducers for use in liquid environments (Shajii et al. 1992)47, enabled by wafer bonding to have the floating mass made of silicon and have the strain gauges electrically insulated. Over the 1990s, MIT research teams further refined this design by introducing optical transduction to improve the sensor resolution in low-speed configurations (in the mPa range), also enabling dynamic measurements up to 10 kHz (Padmanabhan et al. 1997)48.

Mark Sheplak, who did postdoctoral work at MIT between 1995 and 1998, brought WSS balance knowledge to the University of Florida and reported continuous iterative developments on the design up to this day (as of 2025). One of the main challenges in flow measurement in general is to accurately generate fully characterized flow configurations, in order to calibrate the sensors. This is particularly true for dynamic calibrations, as it is complex to generate a physical flow step input or sinusoidal sweep. Answering this challenge, Sheplak’s research group developed a novel calibration method for wall shear stress sensors, based on standing acoustic waves in a tube (Sheplak et al. 1998)49, generating a sinusoidal velocity field. Chandrasekaran et al. (2005)50 reported dynamic calibration of WSS balances with optical transduction up to 20 kHz using this apparatus. Chandrasekharan et al. (2011)51 reported an iteration of the design with capacitive transduction, with an improvement in dynamic range of one order of magnitude. Mills et al. (2015)52 achieved hydraulic smoothness by managing to route the electrical contacts to the wafer’s backside, which resulted in a high TRL, packaged sensor system. The company IC2 was created in 2001 in order to exploit the intellectual property related to direct WSS sensors. Eventually, these two decades of iterations led to the commercialization of these sensors in the DirectShear series. In 2025, IC2 partnered with Dantec Dynamics in order to broaden their reach. Currently, they sell the complete system compatible with the National Instruments PXI platform.

Figure 1.11.
Technology maturation developments of the Microscale Differential Capacitive Wall Shear Stress Sensor developed at the University of Florida.

(a) Shear stress sensor design with capacitive transducers designed by Chandrasekharan et al. (2011)51.
(b) Packaging of the sensor with backside electrical contacts to achieve hydraulic flush-mounting (Mills et al. 2015)52.
(c) Conditioning electronics of the capacitive transducers (Mills et al. 2015)52.
wall heater Thermal boundary layer pushed by the flow probes u(y)
Figure 1.12.
Thermal shear stress measurement principle. The flow both cools down the heater and deforms the thermal boundary layer, which can be probed using passive thermistors.

#Thermal wall shear stress sensors

While thermal WSS sensors operate similarly to out-of-plane hot wires, their heating element is flush-mounted on the wall surface (figure 1.12). This configuration makes the forced convection losses linked to the WSS instead of the velocity. These sensors are an extension of classic hot wires, and are called “hot films” because the heating element, usually nickel, is deposited onto a flexible polyimide, which can be glued to a wall. Because of their similarities to hot wires, hot films can be operated with the same CC and CTA control circuits. Dantec Dynamics commercializes the 55R glue-on probe series for use in air or water. The robustness and ease of integration of these sensors is offset by the considerable conduction losses to the substrate, which, unlike hot wires, occur on the entire length of the heating element. As a consequence, glue-on hot films are much less sensitive than their prong-mounted counterparts.

Like the other sensors presented above, thermal WSS sensors have benefited from technological advances in MEMS for the last thirty years. In addition to reducing the measurement volume and improving the bandwidth, the challenge was to thermally insulate the heating element as much as possible to gain sensitivity. One year prior to the first micromachined hot wire anemometer, Ho’s team introduced a microscale thermal WSS sensor made of a polysilicon heater on a silicon nitride diaphragm (Liu et al. 1994)53. Various lengths were investigated, ranging from 80 to 200 µm. While the vacuum cavity under the membrane was shown to greatly improve the sensitivity, the researchers noted a decrease in the frequency response due to a greater heating volume (Huang et al. 1996)54. Nonetheless, the batch fabrication advantages of MEMS technologies enabled such hot films to be manufactured in parallel onto a single imaging chip for distributed WSS measurement. The sensors are spaced 300 µm apart. Experiments were conducted to study flow separation in different configurations: fully developed turbulent flow on a flat plate (Jiang et al. 1996)55, stalling airfoil (Yoshihiro et al. 1997)56 and turbulent channel flow (Miyagi et al. 2000)57. In parallel with the development of skin friction balances, Mark Sheplak’s team presented a similar membrane WSS sensor, made of a 200 × 4 × 1.5 µm platinum heater on a silicon nitride membrane (Sheplak et al. 2002)58. It has been dynamically calibrated up to 7 kHz in the University of Florida plane wave tube generation setup.

In Europe, the technological advances in MEMS flow sensors were driven by two main projects: AEROMEMS from 1997 to 2001 (Warsop 1999)59, and AEROMEMS II from 2002 to 2005 (Warsop 2004)60. Beyond sensor engineering, they were large-scale multidisciplinary projects aimed at implementing reactive flow separation control using MEMS sensors and actuators. A year prior to the beginning of AEROMEMS, Ernst Obermeier’s team at TU Berlin presented a hybrid structure between the hot wire and hot film, for pipe gas flow sensing applications. A calorimetric structure (central heater flanked by two passive resistors) is deposited on a single supporting bridge, with a backside cavity and flow guide to maximize the thermal transfer through the fluid (Qiu et al. 1996)61. In the AEROMEMS framework, they tested their microfence sensor (mentioned above) in a separated flow, which is the specific flow configuration targeted by the project (Schober et al. 2004)62. One year later, they introduced a hot-wire wall sensor. Like a hot film, it uses a free-standing heating element, here 800 × 2 × 2 µm, which reduces substrate thermal losses even more effectively than a membrane (Buder et al. 2005)63. Continuing their developments, they introduced a double-wire wall sensor to detect flow direction, which is useful in determining flow separation bubbles. Eight of these sensors were mounted on the chord of an airfoil to correlate the flow separation to the lift coefficient (Buder et al. 2008)64.

Building on these pioneering European developments, the increasing need for accurate WSS measurements across a wide range of turbulent flow regimes has stimulated substantial research efforts toward the development of miniaturized sensors combining high spatial resolution, fast temporal response, and minimal flow disturbance. These requirements are particularly critical in high-Reynolds-number turbulent flows, where near-wall coherent structures and associated wall shear stress fluctuations exhibit complex spatial and temporal dynamics. While the AEROMEMS projects aimed at applying MEMS technologies for flow sensing, it appeared that technological bottlenecks are still yet to be overcome to actually reach the spatiotemporal resolutions needed to perform state-of-the-art flow experiments. For conventional hot-wire sensors, one of the key miniaturization constraints is the need to maintain a sufficiently high length-to-diameter ratioIdeally, \ell/d > 200.



to minimize heat conduction toward the supporting structures and preserve measurement sensitivity. Building on the MEMS innovations discussed above, the community switched to focusing on performance improvements for microscale probes. Namely, the ANR SNAPPER aims at radically bridging the technological gaps, by performing a non-contact heating and measurement on a thermally isolated heater.

2006First report of the NSTAPKunkel et al. at Princeton University2009Patent of a calorimetric WSS sensor designand out-of plane probesViard et al. at IEMN2008Introduction of a direct WSS sensorChandrasekharan et al. at University of Florida2017Introduction of a thermal calorimetric WSS sensor, Weiss et al. at IES Montpellier2027Snapper project,IEMN team2023Flight-testing of WSS sensors on a combat jet IEMN team
Figure 1.13.
Timeline of key research teams involved in the development of MEMS WSS sensors, highlighting major technological milestones.

Our research group at IEMN introduced in 2009 an original multifunctional MEMS sensor concept combining pressure measurements with bipolar wall shear stress detection, enabling the determination of both the magnitude and sign of the local wall friction (Viard et al. 2013)65, (Talbi et al. 2012)66 This approach was particularly relevant for separated and reversing flows, where conventional unidirectional thermal sensors cannot directly distinguish the direction of wall shear stress. The first wind-tunnel calibration and validation of this technology were subsequently achieved by Ghouila-Houri et al. (2016)67. In 2017, the IES group at the University of Montpellier proposed a calorimetric WSS sensor architecture, providing another route toward the measurement of near-wall flow characteristics (Weiss et al. 2017)68. Collectively, these technologies have undergone extensive experimental investigations and successful wind-tunnel validations under different flow conditions, demonstrating the potential of MEMS-based thermal sensing for high-resolution wall shear stress measurements (Kokmanian et al. 2021)69, (Le-The et al. 2021)70, (Ghouila-Houri et al. 2019)71, (Ghouila-Houri et al. 2021)72.

Over the past fifteen years, our group at IEMN, in close collaboration with ONERA, has developed substantial expertise in thermal MEMS technologies dedicated to aerodynamic flow metrology and closed-loop flow control. This long-standing collaboration has encompassed the complete technological chain, from multiphysics modeling and microfabrication to sensor packaging, electronic instrumentation, calibration, and experimental validation in aerodynamic facilities. The resulting devices have been extensively investigated in ONERA wind tunnels under various flow configurations, including subsonic regimes and compressible flows reaching Mach 0.8 (Ghouila-Houri et al. 2021)28, (Ghouila-Houri et al. 2019)71. These developments have been supported by two patents (Viard et al. 2013)65, (Pernod et al. 2011)73 and several research programs, beginning with funding from the EADS between 2006 and 2009, followed by doctoral funding from the French defense innovation agency and the ASTRID CAMELOTT project, from 2014 to 2018. It has been subsequently extended through the CAMELOTT-MATVAL maturation program between 2018 and 2023.

In parallel, the group pioneered the development of an integrated calorimetric WSS sensor capable of measuring both the magnitude and direction of wall friction (Viard et al. 2013)65, (Ghouila-Houri et al. 2016)67. Unlike conventional single-element hot-film sensors, this architecture exploits the asymmetric heat transfer induced by the flow around a central heating element, enabling the detection of flow reversal and the determination of the sign of the wall shear stress. Particular attention was devoted to sensor packaging and aerodynamic integration, including the development of flush-mounted configurations designed to minimize disturbances to the near-wall flow. Figure 1.14 presents the overall sensing concept, the fabricated device incorporating through-silicon vias, and the coaxial packaging architecture developed for robust integration into aerodynamic test surfaces.

The technological maturity of this sensing approach was further demonstrated through the ASTRID-Maturation program, which extended the validation process beyond controlled wind-tunnel environments toward real flight conditions. In particular, flight demonstration campaigns conducted in 2022 and 2023 aboard ultralight and jet aircraft successfully demonstrated the operation of the sensors under representative aerodynamic conditions, including real-time acquisition and air-to-ground transmission of measurement data. These demonstrations marked an important step toward the operational deployment of MEMS-based wall shear stress sensors, confirming the feasibility of integrating miniaturized thermal sensing technologies into airborne measurement systems.

Figure 1.14.
Micro-bridge supported calorimetric wall shear stress sensor HTGS) and iterations toward TRL improvements, at IEMN.

(a) Working principle of the  thermal calorimetric sensor (Ghouila-Houri et al. 2016)74.
(b) Iteration of the  meant for flush-mounting, with contacts routed to the chip backside using  (Mazzamurro et al. 2022)75.
(c) Integration of the  for mounting on aircraft pods (Mazzamurro et al. 2022)75.

#1.2.3 Classification of flow sensing technologies reported in the literature

LegendFlow sensorsDynamic pressureFlowFreestream U (m/s)Stress tau (Pa)MechanicalPiezoresistiveOpticalMetalsSemiconductorsTransductionmethodMeasurementprincipleThermopilesHot wiresNSTAP,Princeton 2015MEMS hot wiresIEMN Lille 2015MEMS PiraniHot filmsPitot tubesKulite pressure sensorsSurface-mounted hot wiresMEMS membranesDantec DynamicsBuchner et al , Bremen 2006Ghouila-Houri et al., IEMN 2016TU Berlin 2005IES Montpellier 2017SiC Griffith University 2015 - presentDe Luca et al., Cambridge 2015Floating massesOkojie, NASA GRC 2004R. Okojie, Kulite, 1998 Dziuban, Wroclaw 1992Berns et al., TU Berlin 2006 (AeroMEMS)Bicking et al., Honeywell (Bicking)CapacitiveThermalnon-MEMSMEMS researchMEMS commercialGhouila-Houri et al., IEMN, 2017, 2022Santagata et al., TU Delft 2011Ho et al. UCLA/CalTech 1994 1st MEMS hot wireTSILin at al, Tokyo/UCLA 2004Padmanabhan 1996University of FloridaIC2 DirectShear Oil film techniqueMicropillars Große & Schröder 2009Microfence Schober, TU Berlin 2004)CapacitiveMills et al. 2018Chandrasekharan et al.2011Li et al. 2007SiC: Mehregany et al. CWRU/NASA GRC 2002OpticalMills et al. 1028Chandrasekharan et al. Florida 2005 Mailly et al. Montpellier 2001 Floating massesObstaclesno known reportsno known reportsno known reportsno known reportsLenterra RealShear
Figure 1.15.
Classification table for different flow measurement techniques.